UV Curing Conveyor Systems...

DYMAX 12", 18" and 25" wide UV curing conveyor systems offer consistent, fast, and safe UV curing. These ultraviolet conveyors are designed for curing of UV curable adhesives, UV curable coatings, and UV curable inks and can be outfitted with standard metal halide (longwave UV), mercury (shortwave UV), or visible bulbs.

Consistent line speed, lamp height, and intensity together provide a consistent UV curing process. DYMAX UV curing conveyors eliminate stray UV light despite utilizing some of the highest-intensity UV curing systems on the market.

 


12" Wide UV Curing Conveyor Systems (UVCS)with 5000-EC Flood Lamps
Not Available in Europe
Operation Manual CoLiteratures  






Maximum UVA Intensity (320-395 nm)1 200 mW/cm2
Maximum UVA Energy
(320-395 nm) @ 5 fpm
1.25 J/cm2 (PN: 39060, 39065, 39080, 39085)
2.5 J/cm2 (PN: 39070, 39075, 39100, 39105)
Line Speed
1 to 27 fpm
Width of Illuminated Area
6" or 12" (depending on the number and orientation of the 5000-EC UV lamps)
Voltage
Lamp(s) - 90V to 260V Conveyor - 120V or 220/230V
Vertical Clearance
4" (Standard) / 6" (with 2" riser, PN 39218) / 10" (with 6" riser, PN 39280)
Overall Dimensions
51" L x 39.5" W x 35" H (130cm x 100cm x 89cm)

Part Numbers:
 
12" UVCS with one center-mounted 5000-EC


12" UVCS with two 5000-ECs (in Series)


12" UVCS with two 5000-ECs (in Parallel)


12" UVCS with four 5000-ECs (2 x 2)
39060 (120V) 
39065 (220-230V)

39070 (120V)
39075 (220-230V)  

39080 (120V) 
39085 (220-230V)  

39100 (120V)  
39105 (220-230V)
Bulb Life
2,000+ hours with less than 20% degradation (typical)
Replacement Bulbs
38560 Metal Halide (Standard)
36970 Mercury (Optional)*
   

1 Intensity readings vary widely depending on the make and model of the radiometer. These intensities were measured with the ACCU-CAL™ 50 radiometer.
* These bulbs are primarily designed for curing UV inks and cationic epoxies.

 

UVCS SideCure™ UV Curing Conveyor System
Operation Manual CoLiterature






Maximum UVA Intensity (320-395 nm)1 200 mW/cm2
Line Speed
1 to 27 fpm
Width of Illuminated Area
6" or 12" (depending on the number and orientation of the 5000-EC UV lamps)
Voltage
Lamp(s) - 90V to 260V Conveyor - 120V or 220/230V
Vertical Clearance
10" (Standard)
Overall Dimensions
51" L x 30" W x 21.5" H (130 cm x 76 cm x 55 cm)

Part Numbers:
 
SideCure™ Conveyor with
TWO Side-Lamp Openings
(Lamps are sold separately)

SideCure™ Conveyor with
FOUR Side-Lamp Openings
(Lamps are sold separately)

SideCure™ 5000-EC UV Curing Lamps
(Lamps sold separately from conveyor)


39767 (120V)  
39766 (220-230V) 


39939 (120V) 
39941 (220-230V)  


39798** (90-264V)
Bulb Life
2,000+ hours with less than 20% degradation (typical)
Replacement Bulbs 38560 Metal Halide (Standard)
36970 Mercury (Optional)*
36658 Visible†
   

1 Intensity readings vary widely depending on the make and model of the radiometer. These intensities were measured with the ACCU-CAL™ 50 radiometer.
* These bulbs are primarily designed for curing UV inks and cationic epoxies.
** These 5000-EC's are specifically designed for the SideCure™. Intensity, footprint, and power requirements are identical, only the connections differ.
† These bulbs are primarily designed for curing UV/Visible curing adhesives through UV-blocked, but transparent substrates.

   

12" Wide UV Curing Conveyors with Fusion F-300s
Operation Manual CoLiterature






Maximum UVA Intensity (320-395 nm)1 2,500 mW/cm2
Maximum UVA Energy
(320-395 nm) @ 5 fpm
2.0 J/cm2
Line Speed
1-27 fpm or 25-115 fpm
Width of Illuminated Area
6" (one Fusion F-300) or 12" (two Fusion F300s)
Voltage
220/230V (50 or 60 Hz)
Vertical Clearance
4" (Standard) / 6" (with 2" riser, PN 39218) / 10" (with 6" riser, PN 39280)
Overall Dimensions
51" L x 39.5" W x 35" H (130cm x 100cm x 89cm)

Part Numbers:
 
12" UV Conveyor with one Fusion F-300
(6" wide curing)

12" UV Conveyor with two Fusion F-300s
(12" wide curing)


39150 (1-27 fpm)  
39275 (25-115 fpm)  

39160 (1-27 fpm)
39276 (25-115 fpm)  
Bulb Life
5,000 hours with essentially no degradation
Replacement Bulbs
36399 Standard "D" bulb, Metal Halide
36441 Optional "H" bulb Mercury*
   

1 Intensity readings vary widely depending on the make and model of the radiometer. These intensities were measured with the ACCU-CAL™ 50 radiometer.
*These bulbs are primarily designed for curing UV inks and cationic epoxies.

   

 
SINGAPORE
33 Ubi Ave 3, #04-23 VERTEX
Singapore 408868
Tel 65 6270 2188
Fax 65 6270 9188
MALAYSIA
PT1866 Tingkat Perusahaan 6
Prai Free Industrial Zone, 13600 Prai 
Penang, Malaysia
Tel 604 390 5882 
Fax 604 390 0082
THAILAND
8 Soi Lasalle 77, Kwaeng Bangna, Khet Bangna
Bangkok 10260, Thailand
Tel 66 2361 2926, 66 2361 2927  
Fax 66 2361 2928
HONG KONG
33 Ubi Ave 3, #04-23 VERTEX
Singapore 408868
Tel 852 8199 0955  
Fax 65 6270 9188
blaze
©2012 Blaze Technology Pte Ltd, Specifications subject to change without notice.
Email: sales@blazeasia.com | Website: www.blazeasia.com
blaze