Home > Products > UV
Spot Lamps |
|
| |
|
| |
|
High Intensity
UV/Visible
Light Curing Spot Lamps
DYMAX spot cure units
typically cure UV and visible curable adhesives and
coatings in 1 to 10 seconds. These units are ideal for
R&D laboratory environments as well as low- and
high-volume production applications in medical, industrial,
electronics, automotive, and optical industries.
DYMAX spot curing units can be supplied with a wide
variety of standard or customized light delivery choices.
Lightguide options available from DYMAX include various
diameters (3 mm, 5 mm, and 8 mm), various lengths (1
meter is standard) to 6 meters, liquid or fiber, and
single or multi-furcated configurations.
|
|
|
|
|
NEW!
BlueWave® LED Prime UVA Specifications
CE Marked - Available Globally
|
| Output |
>15
W/cm2 adjustable from 0% to 100% |
|
Power Requirements |
100-240V, 47-63 Hz (Auto Ranging) |
| LED
Timer
|
Digital
LCD timer up to 99.99 seconds; manual or timed exposure |
| LED
Activation |
Foot
switch or PLC |
| Cooling
|
Single filtered fan; thermally controlled to maintain
proper LED temperature |
| Hour
Meter |
Digital LCD |
| Housing
Dimensions |
8.375"
x 8.75" x 5.5" (21.3 cm x 22.2 cm x 14.0 cm) |
| Weight |
5.40
lbs. (2.45 kg) |
| Unit
Warranty |
1
year from purchase (lightguide not included) |
| Part
Numbers |
40321 (includes
5mm x 1 Meter liquid-filled lightguide PN 5720
40322 (without lightguide) |
| |
| |
|
|
BlueWave®
200 Specifications
CE Marked - Available Globally
>18,000 mW/cm2

|
| Intensities |
| Total
|
(280-450
nm) |
40+
W/cm2 |
| Visible
|
(400-450
nm) |
17+
W/cm2 |
| UVA1
|
(320-395
nm) |
17+
W/cm2 |
| UVB
|
(280-320
nm) |
7+
W/cm2 |
|
|
Power Requirements |
90-264, 47-63 Hz |
| Power
Supply
|
Solid-state,
200 Watt |
| Reflector
|
Elliptical;
glass with dichroic coating to reflect UV and minimize
IR |
| Shutter
Time |
Digital LCD timer up to 99.99 seconds; manual or timed
shutter |
| I/O
Port |
9 pin D- sub-miniature connector |
| Signals (PLC
Integration) |
Inputs
Shutter activate; shutter deactivate |
| |
Outputs
Shutter opened; shutter closed; shutter fault |
| Cooling |
Filtered,
dual-fan arrangements; thermally controlled to maintain
proper lamp temperature |
| Hour
Meter |
Digital
LCD; lamp hours and bulb hours (re-settable) |
| Overall
Dimensions |
12.0"
x 12.0" x 6.5" (30.6 cm x 30.6 cm x 16.5 cm) |
| Weight |
12
lbs. (5.4 kg) |
| System
Warranty |
One
year from purchase |
| Bulb
Warranty |
2,000
hours (no intensity warranty during 2,000 hours, only
lighting) |
| Replacement
Bulb PN |
38465 |
| Part
Numbers
North American Version (115V standard plug)
International Version (with no plug)
|
38905
38605 |
| *
As measured through a 5 mm liquid lightguide with a DYMAX
ACCU-CAL™ 50 Radiometer (320-395 nm) (39560) |
| |
|
|
BlueWave® 75
Specifications
CE Marked - Available Globally
>9,000 mW/cm2

|
| Intensities |
| Total
|
(280-450
nm) |
19+
W/cm2 |
| Visible
|
(400-450
nm) |
9+
W/cm2 |
| UVA1
|
(320-395
nm) |
9+
W/cm2 |
| UVB
|
(280-320
nm) |
1.5 W/cm2
|
|
| |
Manual
from 1% to 100% output |
| Power
Requirements |
90-264
VAC, 50-60 Hz |
| Power
Supply |
Solid-state,
200 Watt |
|
Bulb
|
75
Watt high-pressure, short-arc bulb included; replacement
in less than one minute |
| Reflector
|
Elliptical;
glass with dichroic coating to reflect UV and minimize
IR |
| Shutter
Time |
Digital
LCD timer up to 99.99 seconds; manual or timed shutter
|
| Shutter
Activation |
Foot
switch or PLC |
| Cooling |
Filtered,
single arrangement; thermally controlled to maintain proper
lamp temperature |
| Hour
Meter |
Digital
LCD; lamp hours and bulb hours (re-settable) |
| Overall
Dimensions |
12.0"
x 12.0" x 6.5" (30.5 cm x 30.5 cm x 16.5 cm) |
| Weight |
14
lbs. (6 kg) |
| System
Warranty |
One
year from purchase |
| Bulb
Warranty |
Ignition
warranted for 2,000 hours |
| Replacement
Bulb PN |
40205 |
| Part
Numbers
North American Version (115V standard plug)
International Version (with no plug)
|
40078
40077 |
| *
As measured through a 5 mm liquid lightguide with a DYMAX
ACCU-CAL™ 50 Radiometer (320-395 nm) (39560) |
| |
|
|
BlueWave®
50 AS Specifications
Available Globally (except Europe)
>3,000 mW/cm2

|
| UV
Output |
>3,000
mW/cm2 initial intensity1 |
| Power
Requirements |
90-265
volts, 47-63 Hz |
| Power
Supply
|
Solid State, 50
Watt 47-63 Hz |
| Bulb
|
50 Watt short arc
metal halide; bulb replacement in under a minute |
| Reflector
|
Elliptical;
glass with dichroic coating to reflect UV and minimize
IR |
| Shutter
Time |
Digital
LCD timer up to 99.99 seconds; manual or timed shutter
|
| Shutter
Activation |
Foot
switch or user-supplied signal |
| Cooling |
Filtered,
dual-fan arrangements; thermally controlled to maintain
proper lamp temperature |
| Hour
Meter |
Digital
LCD |
| Overall
Dimensions |
12.0"
x 12.0" x 6.5" (30.6 cm x 30.6 cm x 16.5 cm) |
| Weight |
21
lbs. (9.5 kg) |
| System
Warranty |
One
year from purchase |
| Bulb
Warranty |
2,000
hours |
| Replacement
Bulb PN |
5120 |
Recommended
Lightguides#
(sold separately) |
| 5720
|
(5mm
x 1 Meter liquid-filled lightguide) >3,000
mW/cm2 initial |
|
5721 |
(5mm x 1.5 Meter liquid-filled lightguide) >2,600
mW/cm2 initial |
|
5722 |
(8mm x 1 Meter liquid-filled lightguide) >1,500
mW/cm2 initial |
| |
|
|
| Part
Number |
39370 |
*
As measured through a 5 mm liquid lightguide with a DYMAX
ACCU-CAL™ 50 Radiometer (320-395 nm) (39560)
# Other lightguides available, including fiber optic,
multi-pole, and various lengths |
|
|
©2010 Blaze Technology Pte Ltd, Specifications subject
to change without notice.
|
|
|